Abstract:
This research simulates and forecasts the area as well as the level of pollution dispersion of Muc Son Paper Factory’s wastewater to the downstream of Chu River under two scenarios: Scenario 1 - wastewater treatment system is broken; treatment efficiency is equal to 0; Scenario 2 - wastewater treatment system is working with its designed capacity. The applied results of the MIKE 11 model show that: the impacted area from the plant’s discharge is 0.2 km upstream and 2 km downstream of the confluence point. The simulation results under Scenario 1 show TSS, BOD5 and COD contents being 18.3–35.7 mg/L, 8.3–17.2 mg/L and 12.2–23.7 mg/L, respectively, negatively affect the water environment downstream of Chu river. The results are then compared with measured data to confirm the reliability of the model. This research is a scientific and practical basis for the Muc Son Paper factory to operate the wastewater treatment system and manage the water quality output to ensure environmental regulations. Nghiên cứu này mô phỏng và dự báo diện tích cũng như mức độ phát tán ô nhiễm của nước thải Nhà máy giấy Mục Sơn xuống hạ lưu sông Chu theo hai kịch bản: Kịch bản 1 - hệ thống xử lý nước thải bị hỏng; hiệu suất xử lý bằng 0; Kịch bản 2 - hệ thống xử lý nước thải hoạt động theo công suất thiết kế. Kết quả ứng dụng mô hình MIKE 11 cho thấy: diện tích tác động từ nguồn thải của nhà máy là 0,2 km về phía thượng lưu và 2 km về phía hạ lưu tính từ điểm hợp lưu. Kết quả mô phỏng theo Kịch bản 1 cho thấy hàm lượng TSS, BOD5 và COD lần lượt là 18,3–35,7 mg/L, 8,3–17,2 mg/L và 12,2–23,7 mg/L, ảnh hưởng tiêu cực đến môi trường nước hạ lưu sông Chu. Sau đó, so sánh kết quả với số liệu thực đo để khẳng định độ tin cậy của mô hình. Nghiên cứu này là cơ sở khoa học và thực tiễn để Nhà máy giấy Mục Sơn vận hành hệ thống xử lý nước thải và quản lý chất lượng nước đầu ra đảm bảo quy định về môi trường.